Atex and machine safety management in a compact 45 mm format
Atex dual-channel insulation barrier and controller for built-in machinery safety
Atex safety
ATEX standards
EN 60079-0
EN 60079-11
EN 60079-25
EN 60079-26
ATEX marking
[Ex ia] IIC Ga
[Ex ia] IIIC Da
II(1)GD
Product used in combination with the "ANATOM78S- (PL or OX)-EEX" sensor
Machine Safety
Performance level with AWAX controller: PL = e in accordance with ISO 13849-1
Safety category: 4 in accordance with ISO 13849-1
Time before dangerous failure: MTTFd = 120 years
Cycle before dangerous failure: B10d=100,000 at 5A
Risk duration: 20 ms max.
Cable severing protection: yes (opening of safety lines)
Short-circuit protection and overload protection: yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting.
Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant parallel Indicators: 3 LEDs
Reset: configurable by dip-switch (SR=Automatic, N=manual)
Mounting: symmetrical DIN 35mm rail on DIN 50022
Mounting: IP 54 electrical box
Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum
Temperature: -20°C to +40°C.
Certification: INERIS 06ATEX0007X